subperiosteal implants
Additively Manufactured Lattice-Like Subperiosteal Implants for Rehabilitation of the Severely Atrophic Ridge
- 14 February 2022
- Posted by: anjaform
- Category: Finite Element Studies
Liyun Bai, Lingling Zheng, Ping Ji, Haoyuan Wan, Nazi Zhou, Rui Liu, Chao Wang
Full text link: https://pubmed.ncbi.nlm.nih.gov/34984904/
Additively Manufactured Lattice-Like Subperiosteal Implants for Rehabilitation of the Severely Atrophic Ridge
1. Scientific Reference
- Study title: Additively Manufactured Lattice-like Subperiosteal Implants for Rehabilitation of the Severely Atrophic Ridge
- Authors: Liyun Bai, Lingling Zheng, Ping Ji, Haoyuan Wan, Nazi Zhou, Rui Liu, Chao Wang
- Journal: ACS Biomaterials Science & Engineering
- Publication year: 2022
- DOI:1021/acsbiomaterials.1c00962
2. Scientific Background
Managing patients with advanced alveolar ridge atrophy remains one of the greatest challenges in implant dentistry. In situations where residual bone volume is insufficient for conventional endosseous implants, alternative rehabilitation strategies must be considered. Subperiosteal implants have regained attention in recent years, largely because digital workflows and additive manufacturing now enable the production of highly customized devices that closely match each patient’s anatomy.
Despite these technological advances, the long-term success of subperiosteal implants depends on more than anatomical adaptation. Their biomechanical behavior and biological integration are essential factors influencing clinical stability and functional performance. This study explores whether a lattice-like implant architecture, produced through metal additive manufacturing, can improve stress distribution while promoting bone formation at the implant–bone interface. By combining computational modeling, preclinical evaluation and preliminary clinical application, the authors provide an integrated assessment of this personalized implant concept.
3. Study Objective
The purpose of this study was to investigate the biomechanical performance and biological behavior of a patient-specific lattice-like subperiosteal implant manufactured using additive manufacturing technology. The authors sought to determine whether this novel design could provide adequate mechanical stability, support new bone formation around the implant, and enable functional rehabilitation of severely atrophic edentulous ridges.
4. Methodology
The investigation combined several complementary research approaches. First, finite element analysis was performed to evaluate stress distribution generated by different implant designs. Based on these simulations, a customized lattice-like subperiosteal implant was digitally designed and fabricated using additive manufacturing.
Biological performance was subsequently assessed in six Beagle dogs through histological evaluation and micro-computed tomography to examine bone response surrounding the implant. Finally, patient-specific implants were placed in edentulous mandibles presenting severe atrophy using an immediate loading protocol. The abstract does not specify the exact number of patients treated or provide additional details regarding patient selection or clinical outcome measures.
5. Main Findings
Finite element simulations demonstrated that the lattice-like configuration distributed mechanical stresses more evenly across the underlying bone surface than conventional implant designs. This biomechanical behavior suggests a potential advantage in reducing localized stress concentration.
Preclinical evaluation revealed newly formed bone both within and around the porous lattice architecture, as confirmed by histological examination and micro-computed tomography. These findings indicate a favorable biological response to the customized implant design.
In the clinical application, patient-specific subperiosteal implants remained functional throughout a 12-month observation period without reported pain or infection. Radiographic assessment performed at the end of follow-up demonstrated evidence of new bone formation and osseointegration. According to the authors, these observations support the mechanical stability and clinical feasibility of lattice-like 3D-printed subperiosteal implants for rehabilitation of severely atrophic ridges.
6. Clinical Analysis
Rather than simply introducing another customized implant, this study proposes a structural redesign intended to optimize both biomechanics and biological integration. The lattice-like architecture represents the key innovation, aiming to improve load transfer while creating an environment that facilitates bone ingrowth.
An important strength of the investigation is the combination of computational analysis, animal experimentation and preliminary clinical implementation. This multi-level approach provides complementary evidence supporting the concept before broader clinical adoption. The histological findings are particularly noteworthy, as they suggest that the implant architecture may encourage intimate interaction between newly formed bone and the implant surface.
Nevertheless, these encouraging results should be interpreted cautiously. The clinical evidence remains limited, with the abstract providing no information regarding the exact number of treated patients or detailed clinical outcome measures. Furthermore, the observation period is restricted to one year, preventing any conclusions regarding long-term biological stability, prosthetic complications or implant survival. Consequently, this work should primarily be viewed as a proof-of-concept study demonstrating feasibility rather than definitive clinical validation.
7. Clinical Applications
The findings suggest potential applications for customized lattice-like subperiosteal implants in patients presenting severe alveolar ridge atrophy where conventional implant placement may be challenging.
The study also illustrates how digital planning and additive manufacturing can be integrated into personalized implant rehabilitation, allowing implants to be specifically designed according to individual anatomy. The observed bone response further supports continued investigation of porous lattice structures in future implant designs.
However, based solely on the available data, these findings should not be interpreted as sufficient evidence to recommend routine clinical implementation.
8. Level of Evidence, Limitations and Transparency
This publication represents a preclinical investigation combined with an early clinical feasibility study, integrating finite element analysis, animal experimentation and preliminary human application.
Accordingly, the overall level of evidence remains moderate. The principal limitations identifiable from the abstract include the limited clinical data, the absence of information regarding the number of treated patients, and a follow-up period restricted to 12 months.
No conflicts of interest or funding disclosures are reported within the abstract provided. Therefore, this information cannot be assessed from the available material.
The conclusions should be considered preliminary until confirmed by larger prospective clinical studies with longer follow-up periods.
9. Key Study Highlights
- Study design: Preclinical study with preliminary clinical validation.
- Level of evidence:
- Study population: Six Beagle dogs and edentulous patients with severe mandibular atrophy.
- Number of patients: Not specified in the available abstract.
- Clinical follow-up: 12 months.
- Primary outcome: Biomechanical stability and biological integration of a customized lattice-like subperiosteal implant.
- Main finding: Improved stress distribution, evidence of new bone formation and maintained implant function throughout follow-up.
- Scientific conclusion: Lattice-like additively manufactured subperiosteal implants demonstrated promising biomechanical and biological characteristics for rehabilitation of severely atrophic ridges.
- Study limitations: Limited clinical evidence, unspecified patient number and relatively short follow-up.
10. Scientific Impact
This study contributes to the growing body of research exploring digitally designed, patient-specific subperiosteal implants manufactured through additive technologies. Its originality lies in combining structural optimization with biological validation rather than focusing solely on customization.
The findings provide preliminary evidence supporting the feasibility of lattice-like architectures for improving both mechanical performance and tissue integration in severely atrophic jaws. Although the clinical experience remains limited, the study establishes an important foundation for future investigations into personalized implant rehabilitation.
Rather than defining a new clinical standard, this work expands current knowledge and highlights the potential of advanced manufacturing technologies in implant dentistry. Larger prospective clinical studies with extended follow-up will be required to determine whether these promising early observations translate into predictable long-term outcomes.
11. Editorial Conclusion
This investigation presents an innovative approach to subperiosteal implant rehabilitation by combining patient-specific digital design with additively manufactured lattice-like structures. The reported biomechanical, biological and preliminary clinical findings support the feasibility of this concept for managing severe ridge atrophy. However, the available evidence remains exploratory, and broader clinical validation will be necessary before firm conclusions regarding long-term effectiveness and routine clinical use can be established.