subperiosteal implants
The Evolution of Custom Subperiosteal Implants for Treatment of Partial or Complete Edentulism in Patients with Severe Alveolar Ridge Atrophy
- 19 June 2024
- Posted by: anjaform
- Category: Literature Review
Jan Łoginoff, Agata Majos, Marcin Elgalal
Full text link: https://pubmed.ncbi.nlm.nih.gov/38930111/
The Evolution of Custom Subperiosteal Implants for Treatment of Partial or Complete Edentulism in Patients with Severe Alveolar Ridge Atrophy
1. Scientific Reference
- Study Title: The Evolution of Custom Subperiosteal Implants for Treatment of Partial or Complete Edentulism in Patients with Severe Alveolar Ridge Atrophy
- Authors: Jan Łoginoff, Agata Majos, Marcin Elgalal
- Journal: Journal of Clinical Medicine
- Year of Publication: 2024
- DOI: 10.3390/jcm13123582
2. Scientific Background
Managing severe alveolar ridge atrophy remains one of the greatest challenges in contemporary implant dentistry. While conventional endosseous implants represent the standard of care for most edentulous patients, extensive bone resorption often requires advanced regenerative procedures before implant placement can be considered. These interventions may increase surgical complexity, treatment duration, and patient morbidity.
Subperiosteal implants were originally introduced as an alternative for patients with insufficient bone volume but gradually fell out of favor following the widespread adoption of osseointegrated root-form implants. Recent advances in three-dimensional imaging, digital treatment planning, computer-aided design, and additive manufacturing have renewed scientific interest in this treatment concept. This review explores how these technological developments have transformed custom-made subperiosteal implants into a more precise and potentially less invasive solution for carefully selected patients with advanced maxillary or mandibular atrophy.
3. Study Objective
The purpose of this narrative review was to examine the historical development and contemporary evolution of custom-made subperiosteal implants for the rehabilitation of partial or complete edentulism in patients with severe alveolar ridge atrophy. The authors aimed to describe how advances in diagnostic imaging, CAD/CAM technologies, and additive manufacturing have influenced implant design, surgical protocols, and reported clinical outcomes while discussing the remaining challenges associated with this treatment approach.
4. Methodology
This publication is a narrative literature review. Rather than presenting new clinical data, the authors synthesize historical and contemporary publications describing the evolution of subperiosteal implant therapy from its introduction during the 1940s to current digitally designed patient-specific implants.
The review discusses developments in implant materials, imaging modalities, manufacturing techniques, surgical procedures, and published clinical outcomes. Two comprehensive tables summarize representative studies on both conventional and modern subperiosteal implant systems. The article does not report a systematic search strategy, predefined inclusion criteria, or formal assessment of methodological quality, which is consistent with the characteristics of a narrative review rather than a systematic review or meta-analysis.
5. Key Findings
The review demonstrates that subperiosteal implant therapy has undergone a profound transformation over the past several decades. Early implant systems were associated with significant technical limitations, including invasive bone impression procedures, difficulties in achieving accurate adaptation to the underlying bone, relatively high complication rates, and inconsistent long-term clinical performance. Historical studies summarized by the authors reported survival rates declining to approximately 50–60% after 15 years in some patient cohorts.
Modern subperiosteal implants have benefited from a completely digital workflow that integrates computed tomography (CT) or cone beam computed tomography (CBCT), computer-aided design and manufacturing (CAD/CAM), and direct metal laser sintering (DMLS). These technologies enable the fabrication of patient-specific titanium implants designed to conform precisely to individual skeletal anatomy while simplifying the surgical workflow into a predominantly single-stage procedure.
The clinical studies reviewed by the authors generally reported encouraging short- and medium-term outcomes. Among the publications discussed were a retrospective study involving 70 patients, reporting a 95.8% implant survival rate after two years, a case series in which all ten implants remained functional after one year, and another study reporting a 93.75% survival rate following six months of follow-up. However, the review also highlights publications describing biological and mechanical complications, including implant frame exposure, infection, and implant mobility, emphasizing that clinical outcomes remain variable across different studies and treatment protocols.
6. Clinical Analysis
One of the principal contributions of this review is its demonstration that the renewed interest in subperiosteal implants is driven not by a reconsideration of historical techniques, but by the integration of modern digital technologies into implant design and manufacturing. Rather than representing a simple refinement of earlier devices, contemporary patient-specific subperiosteal implants reflect an entirely different clinical concept built upon three-dimensional imaging, virtual planning, and additive manufacturing.
The implementation of CT and CBCT imaging has fundamentally changed preoperative planning by allowing surgeons to create highly accurate three-dimensional models of the patient’s maxillary or mandibular anatomy. Combined with CAD/CAM software, this digital workflow enables individualized implant frameworks that closely match the residual bone surface. Consequently, traditional intraoperative bone impression techniques—which previously required extensive surgical exposure and two-stage procedures—can largely be avoided.
From a clinical perspective, these developments are particularly relevant for patients with severe alveolar ridge atrophy who are poor candidates for conventional endosseous implant placement without extensive bone augmentation. In carefully selected cases, custom-made subperiosteal implants may provide an alternative rehabilitation strategy while potentially reducing surgical morbidity associated with major reconstructive procedures. Nevertheless, the authors do not advocate replacing conventional implant therapy but instead position these implants as an additional treatment option for specific anatomical situations.
The review also emphasizes the importance of interpreting the currently available evidence with caution. Most published studies involve observational designs, relatively limited patient populations, and heterogeneous surgical protocols. Furthermore, reported complications—including early or delayed framework exposure, infection, and implant mobility—indicate that successful outcomes cannot be assumed universally. While recent technological advances appear promising, they do not eliminate the need for careful patient selection and long-term clinical monitoring.
Finally, the authors conclude that additional prospective clinical investigations with longer follow-up periods are necessary before definitive conclusions regarding the long-term predictability of modern subperiosteal implants can be established. The current literature supports growing confidence in this technology but does not yet provide sufficient evidence to define it as a standard treatment modality for all patients with severe alveolar bone loss.
7. Clinical Applications
According to the literature reviewed, custom-made subperiosteal implants may represent a valuable treatment option for patients with severe maxillary or mandibular alveolar ridge atrophy, particularly when conventional endosseous implant placement would require extensive bone augmentation procedures.
Their clinical application relies on a comprehensive digital workflow, integrating CT or CBCT imaging, virtual implant planning, CAD/CAM design, and titanium additive manufacturing. This combination enables the production of patient-specific implants that closely conform to individual skeletal anatomy while simplifying the surgical procedure compared with historical techniques.
The review specifically discusses their use in the rehabilitation of partial and complete edentulism associated with advanced alveolar bone resorption. However, the available evidence does not support extending these findings to all implant patients. Instead, the authors present custom subperiosteal implants as a specialized therapeutic option that may be appropriate in selected clinical scenarios while acknowledging the need for further long-term validation.
8. Level of Evidence, Limitations and Transparency
This publication is a narrative literature review, providing a historical and technological overview rather than a quantitative synthesis of evidence. Consequently, its level of evidence is lower than that of a systematic review, meta-analysis, or randomized controlled clinical trial. Its primary value lies in integrating published data to illustrate how technological innovations have reshaped the role of custom-made subperiosteal implants in contemporary implant dentistry.
The studies discussed throughout the review differ substantially in patient selection, implant design, manufacturing techniques, surgical protocols, follow-up duration, and clinical outcome measures. This heterogeneity limits direct comparisons between publications and prevents definitive conclusions regarding the superiority of one treatment approach over another. Moreover, the review does not describe a predefined literature search strategy, inclusion and exclusion criteria, or a formal risk-of-bias assessment, which is consistent with its narrative design.
The authors themselves emphasize that although recent technological advances appear promising, additional long-term clinical investigations are required before the widespread applicability of modern custom-made subperiosteal implants can be fully confirmed.
Regarding transparency, the authors declare no conflicts of interest. The study was supported by the Medical University of Lodz (Poland), and no industrial sponsorship or manufacturer involvement is reported in the article.
9. Study Highlights
- Study Type: Narrative literature review.
- Level of Evidence: Moderate to low, consistent with a narrative review.
- Population / Studies Reviewed: Not specified in the article.
- Number of Patients or Implants: Not applicable to the review itself; the cited studies include patient cohorts and case series of varying sizes.
- Follow-up Duration: Variable across the reviewed publications, ranging from several months to multiple years.
- Primary Focus: Evolution of custom-made subperiosteal implants, including imaging, digital design, manufacturing technologies, surgical techniques, and reported clinical outcomes.
- Main Findings: Digital technologies—including CT/CBCT imaging, CAD/CAM planning, and direct metal laser sintering—have significantly improved the design and clinical feasibility of patient-specific subperiosteal implants.
- Scientific Conclusion: Modern custom-made subperiosteal implants represent a promising treatment alternative for selected patients with severe alveolar ridge atrophy, although further long-term clinical evidence is required.
- Main Limitations: Narrative review design, heterogeneous source studies, absence of systematic methodology, and limited availability of long-term high-level clinical evidence.
10. Scientific Impact
This review provides a comprehensive overview of how digital technologies have revitalized interest in subperiosteal implant therapy. Rather than simply documenting historical developments, it illustrates how innovations in diagnostic imaging, virtual planning, CAD/CAM workflows, and additive manufacturing have fundamentally changed the design philosophy of these implants. The article therefore contributes to understanding why a technique once considered largely obsolete is now being reconsidered within modern implant rehabilitation.
An important contribution of the review is its balanced interpretation of the available evidence. While several recent clinical studies report encouraging survival rates and favorable functional outcomes, the authors avoid overstating these findings and acknowledge the variability observed among published reports. This cautious perspective reinforces the importance of evidence-based clinical decision-making when considering patient-specific subperiosteal implants.
From a scientific standpoint, the review also identifies important directions for future research. Standardized clinical protocols, larger prospective cohorts, and extended follow-up periods will be essential to determine the long-term predictability, biological stability, and prosthetic performance of these customized implant systems. As digital implantology continues to evolve, this article provides an informative reference summarizing the current state of knowledge while highlighting the remaining gaps that should be addressed through future investigations.
11. Editorial Conclusion
This review illustrates the remarkable transformation of subperiosteal implant therapy through the integration of advanced imaging, digital planning, and additive manufacturing technologies. Custom-made titanium frameworks have renewed the clinical relevance of this treatment concept, particularly for patients with severe alveolar ridge atrophy who may not be suitable candidates for conventional implant rehabilitation. Although the available evidence is encouraging, it is primarily derived from observational studies and case series. Accordingly, the findings should be interpreted cautiously until larger prospective studies with long-term follow-up further clarify the predictability and clinical indications of modern patient-specific subperiosteal implants.