1. Scientific Reference
- Study Title: Personalized subperiosteal implant-supported obturator for the rehabilitation of rhino-orbit-cerebral mucormycosis sequela: A case report.
- Authors: Julia Parras-Hernández, Álvaro Tofé-Povedano, Javier Herce-López, David Matute-García, Elena Martínez-Carapeto, Guadalupe Cuadrado-Caballero, Ángel Rollón-Mayordomo.
- Journal: Experimental and Therapeutic Medicine.
- Publication Year: 2024.
- DOI: 10.3892/etm.2024.12727.
2. Scientific Background
Extensive maxillary defects remain among the most demanding challenges in oral and maxillofacial surgery. Patients who undergo radical surgery for rhino-orbito-cerebral mucormycosis frequently experience severe functional impairment involving speech, mastication, swallowing, and facial aesthetics due to the loss of hard and soft tissues.
Traditional rehabilitation generally relies on microvascular free-flap reconstruction or prosthetic obturation. However, these approaches are not suitable for every patient. Previous reconstructive failure, insufficient residual bone, complex anatomical defects, or refusal of additional surgery may significantly restrict treatment options.
Advances in three-dimensional imaging, digital treatment planning, additive manufacturing, and CAD/CAM technologies have enabled the development of customized subperiosteal implants designed to match each patient’s residual anatomy. Rather than relying on conventional endosseous implant placement, these patient-specific devices provide prosthetic support by engaging preserved cortical bone. This case report explores the clinical application of this digital workflow in an exceptionally complex reconstructive scenario.
3. Study Objective
The purpose of this report was to describe the clinical use of a customized subperiosteal implant (PSI) supporting a removable implant-retained obturator in a patient presenting severe maxillary defects following rhino-orbito-cerebral mucormycosis. After the failure of microvascular fibula flap reconstruction and the patient’s refusal to undergo another reconstructive procedure, the authors sought to determine whether a patient-specific implant could restore oral function while closing the oro-nasal-antral communication. The study also documents the short- to medium-term clinical outcome of this individualized rehabilitation approach.
4. Methodology
This publication is a single-patient case report describing the treatment of a 53-year-old man with a Brown class IIIb maxillary defect associated with right orbital exenteration and bilateral ethmoidectomy following surgical management of rhino-orbito-cerebral mucormycosis. A previous reconstruction using a microvascular fibula free flap had failed because of internal jugular vein thrombosis occurring on the third postoperative day.
Treatment planning relied on a fully digital workflow combining conventional silicone impressions, facial computed tomography, cone-beam CT imaging, virtual prosthetic simulation, and CAD/CAM design. The imaging datasets were merged to produce a patient-specific titanium (Ti6Al4V) subperiosteal implant manufactured through additive laser sintering. The implant incorporated six prosthetic connections designed to retain a removable obturator. After surgical fixation to the zygomatic bones and the left zygomaticomaxillary buttress, the definitive prosthesis was delivered two weeks later. Clinical follow-up extended to 18 months.
5. Main Findings
At the 18-month follow-up, the rehabilitation demonstrated a favorable clinical outcome. The customized subperiosteal implant remained stable, with no reported mobility or biological complications throughout the observation period. Although part of the implant framework intentionally remained exposed within the oral cavity, the authors did not observe peri-implant soft tissue complications or other adverse biological events related to this design.
From a prosthetic perspective, the removable implant-supported obturator successfully restored occlusion with the mandibular dentition while providing complete closure of the oro-nasal-antral communication. This rehabilitation improved the patient’s ability to eat and speak and facilitated daily hygiene because the prosthesis could be removed for cleaning. Prosthetic stability and adaptation remained satisfactory during follow-up, with no evidence of implant loosening or prosthetic instability.
Based on these observations, the authors suggest that customized subperiosteal implants may represent a valuable rehabilitation option for carefully selected patients in whom conventional reconstructive procedures are either unsuccessful or declined. However, they emphasize that this conclusion is derived from a single clinical case and should not be interpreted as evidence supporting routine clinical use.
6. Clinical Analysis
This case illustrates one of the most challenging scenarios encountered in maxillofacial rehabilitation. Following the failure of microvascular reconstruction and the patient’s refusal to undergo additional reconstructive surgery, conventional treatment options became extremely limited. Rather than replacing endosseous implants in an atrophic maxilla, the customized subperiosteal implant served as an individualized prosthetic foundation capable of restoring oral function despite extensive maxillary tissue loss.
A major strength of this approach lies in its ability to utilize preserved cortical bone structures—particularly the zygomatic and nasal buttresses—as stable anchorage sites. The complete digital workflow, integrating three-dimensional imaging, CAD/CAM planning, and additive manufacturing, enabled the implant to be tailored precisely to the patient’s remaining anatomy. This degree of customization is particularly relevant in cases where standard implant protocols cannot provide predictable support because of severe anatomical deficiencies.
The favorable 18-month outcome demonstrates that this individualized strategy successfully restored essential oral functions while maintaining implant stability. Nevertheless, the findings should be interpreted cautiously. As a single case report, the study provides only a low level of clinical evidence and does not establish superiority over conventional reconstructive surgery or alternative prosthetic approaches. Furthermore, the long-term biological behavior of the implant portion intentionally exposed to the oral cavity remains uncertain, and the authors specifically identify this issue as requiring further investigation.
Overall, this report highlights the potential role of customized subperiosteal implants as a patient-specific solution for highly complex maxillary defects while reinforcing the importance of careful case selection and individualized treatment planning.
7. Clinical Applications
The findings suggest that customized subperiosteal implants may be considered for selected patients presenting extensive maxillary defects when conventional reconstructive surgery is not feasible or is declined by the patient. Such situations include severe post-maxillectomy defects associated with large oro-nasal-antral communications and insufficient residual bone to support conventional endosseous dental implants.
By combining three-dimensional imaging, digital treatment planning, CAD/CAM technology, and additive manufacturing, clinicians can design patient-specific implants adapted to highly complex anatomical situations. According to the authors, this approach may improve prosthetic support in cases where conventional obturators cannot achieve adequate stability. However, the technique should currently be regarded as an individualized reconstructive option rather than a standard treatment protocol, pending confirmation through larger clinical studies with longer follow-up periods.
8. Level of Evidence, Limitations, and Transparency
This publication is a single-patient case report, representing a low level of clinical evidence. Its conclusions are based on the outcome of one individual and therefore cannot be generalized to broader patient populations.
The principal methodological limitations include the absence of a control group, the inclusion of only one patient, the lack of comparison with alternative reconstructive strategies, and a follow-up limited to 18 months. The authors also acknowledge that additional studies are required to evaluate the long-term biological behavior of the implant segment exposed to the oral cavity.
Regarding transparency, the authors declare no competing interests. They report that Avinent Implant System S.L.U. provided financial and administrative support exclusively for English language editing and state that no additional funding was received. This disclosure should be considered factually when interpreting the study findings.
9. Key Study Highlights
- Study Design: Single-patient case report.
- Level of Evidence: Low (clinical evidence derived from one patient).
- Study Population: One 53-year-old male with extensive maxillary defects following rhino-orbito-cerebral mucormycosis.
- Number of Patients: 1.
- Number of Implants: One customized titanium subperiosteal implant incorporating six prosthetic connections.
- Follow-up Duration: 18 months.
- Primary Outcome: Clinical feasibility of rehabilitating an extensive maxillary defect using a customized subperiosteal implant supporting a removable implant-retained obturator.
- Main Result: At 18 months, the implant remained stable without reported biological complications, while the prosthesis restored speech, mastication, and closure of the oro-nasal-antral communication.
- Scientific Conclusion: The authors suggest that customized subperiosteal implants may provide a rehabilitation option for selected patients with extensive maxillary defects when conventional reconstruction is not feasible or is declined, although further clinical evidence is required.
- Study Limitations: Single clinical case, no control group, limited follow-up, and insufficient long-term data regarding the implant segment exposed to the oral cavity.
10. Scientific Impact
This report expands the clinical literature on customized subperiosteal implants by demonstrating their application in a particularly demanding reconstructive scenario. While most published work has focused on the rehabilitation of severely atrophic jaws, this case explores their use following extensive maxillary destruction caused by rhino-orbito-cerebral mucormycosis and the failure of previous microvascular reconstruction.
Another notable contribution is the comprehensive digital workflow employed throughout treatment. Three-dimensional imaging, virtual planning, CAD/CAM engineering, and additive manufacturing were combined to produce a patient-specific implant precisely adapted to the remaining facial skeleton. This illustrates how digital implantology can facilitate individualized rehabilitation in situations where conventional implant protocols are not applicable.
Although the report cannot establish clinical recommendations because of its low level of evidence, it provides preliminary support for further investigation into customized subperiosteal implants as an alternative reconstructive strategy in carefully selected patients. The authors appropriately emphasize the need for larger clinical series and longer follow-up to evaluate long-term biological stability, prosthetic performance, and treatment predictability.
11. Editorial Conclusion
This case report demonstrates that a customized subperiosteal implant can successfully support prosthetic rehabilitation in a patient with an extensive maxillary defect after failed conventional reconstruction. Through a fully digital CAD/CAM workflow, the individualized implant restored oral function while maintaining satisfactory clinical stability over an 18-month follow-up. Although these findings are encouraging, they originate from a single clinical observation and should therefore be interpreted cautiously. Larger prospective studies with long-term follow-up will be necessary to determine the reproducibility, safety, and broader clinical role of this personalized rehabilitation strategy.