subperiosteal implants
Virtual Surgical Planning and Customized Subperiosteal Implants: A Systematic Review
- 22 April 2025
- Posted by: anjaform
- Category: Literature Review
Al-Nawas, A.-K. Bär
Full text link: https://pubmed.ncbi.nlm.nih.gov/40263044/
Virtual Surgical Planning and Customized Subperiosteal Implants: A Systematic Review
1. Scientific Reference
- Study Title: Virtual Surgical Planning and Customized Subperiosteal Implants: A Systematic Review
- Authors: B. Al-Nawas, A.-K. Bär
- Journal: International Journal of Oral and Maxillofacial Surgery
- Publication Year: 2025
- DOI: 10.1016/j.ijom.2025.04.001
- PMID: 40263044
2. Scientific Background
The rapid evolution of digital technologies has transformed the management of complex implant rehabilitation, particularly in patients with severe jaw atrophy. Advances in virtual surgical planning, computer-aided design (CAD), and additive manufacturing have renewed interest in customized subperiosteal implants, offering patient-specific solutions for anatomical situations where conventional endosseous implant placement may be challenging.
Within this context, the present systematic review examines the current clinical evidence supporting digitally manufactured customized subperiosteal implants. Rather than focusing solely on implant survival, the review explores their clinical indications, biological performance, osseointegration strategies, mechanical reliability, and reported complications. As personalized implant manufacturing becomes increasingly integrated into digital workflows, understanding the strengths and limitations of the available evidence is essential for clinicians involved in oral surgery, implant dentistry, and full-arch rehabilitation.
3. Study Objective
The primary objective of this systematic review was to evaluate the clinical use of digitally manufactured customized subperiosteal implants. Specifically, the authors assessed their indications, functional performance, approaches intended to enhance osseointegration, and overall safety profile by distinguishing between early and late biological and mechanical complications.
4. Methodology
This investigation was conducted as a systematic review following the PRISMA reporting guidelines. Literature searches were performed in the PubMed and Embase databases, covering studies published between 2018 and 2023. Methodological quality was assessed using the Joanna Briggs Institute (JBI) and National Institutes of Health (NIH) appraisal tools.
Twenty-four publications met the inclusion criteria, including six cohort studies, six case series, and twelve case reports. Altogether, the review analyzed 246 customized subperiosteal implants. The mean follow-up period was 17 months. Outcomes included implant functionality, prosthetic indications, implant survival, biological and mechanical complications, and methods used to promote osseointegration.
5. Main Findings
Following a mean follow-up of 17 months, 97.6% of the implants remained functional and demonstrated satisfactory clinical adaptation. Customized subperiosteal implants were predominantly used to support full-arch prosthetic rehabilitation in the maxilla and fixed bridge restorations in both jaws.
Across the included studies, reported implant survival rates ranged from 94.1% to 100%. Early postoperative complications mainly consisted of pain (25%) and swelling (24%). Late complications requiring implant removal were uncommon, with only five reported failures among all included publications. Partial implant exposure was observed in 37% of implants. Although patient satisfaction and aesthetic outcomes were generally described as favorable, these endpoints were infrequently evaluated. Various surface modification strategies—including additively manufactured titanium, acid etching, grit blasting, and polyether ether ketone (PEEK)—were reported to promote osseointegration, but no technique demonstrated clear superiority over another.
6. Clinical Analysis
This systematic review provides a comprehensive overview of the contemporary evidence supporting customized subperiosteal implants produced through digital workflows. The findings suggest that these patient-specific devices may represent a valuable treatment alternative for individuals with severe maxillary or mandibular atrophy, particularly when conventional implant placement or extensive bone augmentation procedures may not be appropriate.
The consistently high proportion of functional implants reported across the included studies supports the technical feasibility of digitally designed subperiosteal implants in carefully selected clinical situations. Nevertheless, the relatively frequent occurrence of partial implant exposure highlights the importance of meticulous soft tissue management and long-term postoperative monitoring.
From an evidence-based perspective, the review also demonstrates that current knowledge remains limited by the nature of the available literature. Most included publications were observational studies, case series, or individual case reports, reducing the overall strength of the evidence. Furthermore, the considerable heterogeneity among study designs prevented quantitative meta-analysis, limiting direct comparisons between implant designs, surface treatments, and clinical protocols. Consequently, these encouraging outcomes should be interpreted as preliminary rather than definitive evidence supporting widespread clinical adoption.
7. Clinical Applications
The findings indicate that customized subperiosteal implants may be considered in the rehabilitation of patients presenting with advanced alveolar bone loss and severe jaw atrophy. According to the reviewed studies, this treatment approach appears particularly relevant for elderly individuals or medically compromised patients in whom extensive reconstructive procedures may not be ideal.
The review also highlights the growing role of digital implant workflows, including virtual surgical planning and CAD/CAM technologies, in the development of patient-specific implant solutions. However, based on the currently available evidence, no particular surface treatment or manufacturing approach can be recommended as clinically superior for enhancing osseointegration.
8. Level of Evidence, Limitations and Transparency
As a systematic review, this study represents a high level of evidence in terms of research methodology. However, the overall strength of its conclusions depends largely on the quality of the included studies, many of which were case reports and case series with relatively short follow-up periods.
The authors specifically acknowledge substantial heterogeneity among the included publications, which prevented the performance of a meta-analysis. They also emphasize the need for larger prospective cohorts with longer follow-up to better establish the long-term safety and effectiveness of customized subperiosteal implants. No information regarding conflicts of interest or financial relationships with implant manufacturers is provided in the available abstract.
9. Key Study Highlights
- Study design: Systematic review.
- Level of evidence: Systematic review including predominantly observational studies, case series, and case reports.
- Number of studies included: 24.
- Number of implants analyzed: 246 customized subperiosteal implants.
- Mean follow-up: 17 months.
- Primary outcome: Clinical performance, indications, osseointegration strategies, and biological and mechanical complications.
- Main finding: 97.6% of implants remained functional, with reported survival rates ranging from 94.1% to 100%.
- Scientific conclusion: Digitally manufactured customized subperiosteal implants appear to be a viable option for the rehabilitation of severely atrophic jaws, although stronger long-term evidence is still required.
- Major limitations: Significant study heterogeneity, inability to perform meta-analysis, relatively short follow-up, and predominance of observational evidence.
10. Scientific Impact
This systematic review contributes to the growing body of literature evaluating digitally manufactured customized subperiosteal implants within modern implant dentistry. By consolidating the available evidence, it provides an updated perspective on a treatment concept that has evolved considerably through advances in digital planning and additive manufacturing.
Rather than establishing definitive clinical recommendations, the review identifies encouraging short-term outcomes while highlighting important evidence gaps. It underscores the need for standardized clinical protocols, longer observational periods, and higher-quality prospective investigations. Consequently, the study serves as both a summary of current clinical experience and a framework for future research aimed at validating customized subperiosteal implant therapy in complex oral rehabilitation.
11. Editorial Conclusion
This systematic review offers a balanced assessment of customized digitally manufactured subperiosteal implants for the management of severely atrophic jaws. The available evidence suggests favorable short-term clinical performance and high implant survival in appropriately selected patients. Nevertheless, the predominance of lower-level clinical studies, the relatively limited follow-up, and substantial methodological heterogeneity warrant cautious interpretation. Future well-designed prospective studies with larger patient populations will be essential to determine the long-term predictability, safety, and clinical effectiveness of this evolving implant rehabilitation approach.