subperiosteal implants
Subperiosteal Implants: A Lost Art Worth Revisiting?
- 27 April 2025
- Posted by: anjaform
- Category: Literature Review
Ryan Goh, Cedryck Vaquette, Omar Breik, Saso Ivanovski, Martin Batstone.
Full text link: https://pubmed.ncbi.nlm.nih.gov/40113431/
Subperiosteal Implants: A Lost Art Worth Revisiting?
1. Scientific Reference
- Study title: Subperiosteal Implants: A Lost Art Worth Revisiting?
- Authors: Ryan Goh, Cedryck Vaquette, Omar Breik, Saso Ivanovski, Martin Batstone.
- Journal: Clinical Implant Dentistry and Related Research
- Year of publication: 2025
- DOI: 10.1111/cid.70025
2. Scientific Background
Managing patients with advanced maxillary or mandibular atrophy remains one of the most demanding challenges in implant dentistry. Although root-form endosseous implants represent the current standard of care, their placement may be restricted by severe bone loss, anatomical limitations, or extensive maxillofacial defects following oncologic surgery. In such situations, conventional implant therapy often requires complex bone augmentation procedures or may not be feasible at all.
Subperiosteal implants were originally developed to address these clinical scenarios and were widely used before the widespread adoption of osseointegrated implants. However, their popularity declined because long-term clinical experience revealed frequent biological and mechanical complications. Advances in digital imaging, CAD/CAM design, additive manufacturing, and patient-specific implant fabrication have renewed interest in this concept. This review explores whether these technological developments may overcome historical limitations and redefine the role of subperiosteal implants in contemporary implant rehabilitation.
3. Study Objective
The purpose of this review is to critically reassess the clinical history of subperiosteal implants and evaluate their potential relevance in modern implant dentistry. The authors examine the reasons behind the historical decline of this treatment modality, review published clinical outcomes, and discuss how contemporary technologies—including CAD/CAM workflows, titanium manufacturing, and digital surgical planning—could improve future clinical performance. Particular attention is given to patients with severe jaw atrophy and those requiring rehabilitation after oncologic maxillofacial surgery.
4. Methodology
This publication is a narrative literature review examining the historical development and current evolution of subperiosteal implants. The authors review landmark clinical studies spanning several decades, describe changes in implant design and materials, and summarize recent reports involving digitally designed patient-specific implants manufactured using direct metal laser sintering (DMLS).
The review discusses prospective and retrospective clinical studies as well as contemporary case series evaluating implant survival, biological complications, mechanical failures, implant design, and advances in digital workflows. Unlike a systematic review, no comprehensive search strategy, formal study selection process, or quantitative meta-analysis is reported in the information provided.
5. Main Findings
The historical literature demonstrates that subperiosteal implants were extensively used between the 1940s and the 1980s before gradually being replaced by endosseous osseointegrated implants, which provided more predictable long-term outcomes. Earlier studies consistently reported increasing complication rates over time, including implant exposure, chronic pain, recurrent infection, bone resorption, implant mobility, and fistula formation.
The review also highlights that not all historical designs performed similarly. In particular, the tripodal mandibular design introduced by Linkow achieved substantially more favorable long-term outcomes than conventional subperiosteal frameworks in several clinical reports.
More recent studies suggest that digital planning, CAD/CAM technology, and additively manufactured titanium implants have significantly improved anatomical accuracy and surgical planning. These innovations enable fully customized patient-specific implants and facilitate prosthetically driven treatment planning. Nevertheless, contemporary reports continue to identify hardware exposure, peri-implant infection, and implant mobility as the most frequently observed complications. Overall, published outcomes remain encouraging in selected clinical situations but vary considerably among studies and follow-up periods.
6. Clinical Analysis
This review provides an important perspective on a treatment concept that has largely disappeared from routine implant practice but may still hold value in carefully selected clinical situations. Rather than attributing the historical decline of subperiosteal implants solely to the concept itself, the authors suggest that many of the reported failures were closely linked to the technological limitations of the time. Earlier implants were fabricated using relatively imprecise techniques, limiting anatomical adaptation and potentially compromising long-term stability.
The introduction of modern digital workflows has substantially changed this landscape. High-resolution computed tomography, CAD/CAM planning, and additive manufacturing now allow clinicians to produce patient-specific titanium frameworks that closely match individual skeletal anatomy. These advances may improve implant adaptation, primary stability, and prosthetically driven planning while reducing the surgical morbidity associated with traditional impression techniques.
Despite these technological improvements, the review makes it clear that biological complications remain a significant concern. Hardware exposure, recurrent peri-implant infection, and implant mobility continue to be reported in contemporary clinical studies. According to the authors, the transmucosal posts likely represent the most vulnerable component of the system, as bacterial colonization at the implant–mucosa interface may spread beneath the periosteum along the subperiosteal framework, promoting chronic inflammation and eventual implant failure.
The review also discusses several potential strategies that could improve long-term outcomes, including careful implant positioning, enhanced fixation using multiple osteosynthesis screws, preservation or augmentation of keratinized mucosa, titanium surface modifications, and the possible integration of bone grafting techniques. However, these concepts are presented as future directions rather than evidence-based clinical recommendations. The available literature remains limited, and the authors emphasize that further long-term clinical research is required before broader clinical adoption can be justified.
7. Clinical Applications
The findings presented in this review suggest that subperiosteal implants may represent a valuable treatment option for highly selected patients in whom conventional implant therapy is difficult or impossible. Potential indications include severe maxillary or mandibular atrophy, extensive alveolar bone loss, and patients requiring oral rehabilitation following ablative maxillofacial cancer surgery.
The incorporation of digital workflows, including CAD/CAM planning and additive manufacturing, enables fully customized implant designs tailored to the patient’s residual anatomy and prosthetic requirements. This individualized approach may facilitate complex implant-supported rehabilitation while potentially reducing the need for extensive reconstructive procedures in selected cases. Nevertheless, because current evidence remains limited and clinical outcomes are still heterogeneous, subperiosteal implants should presently be considered a specialized treatment option reserved for carefully selected patients managed by experienced multidisciplinary teams.
8. Level of Evidence, Limitations and Transparency
This publication is a narrative literature review, providing an expert synthesis of historical and contemporary evidence rather than a systematic evidence appraisal. Consequently, its level of evidence is lower than that of a systematic review or meta-analysis, as no predefined search strategy, formal study selection process, or quantitative evidence synthesis is reported in the available information.
The review draws upon studies with considerable methodological diversity, including prospective investigations, retrospective studies, and case series involving different implant designs, surgical protocols, and follow-up durations. The authors also acknowledge that published evidence regarding modern CAD/CAM-manufactured subperiosteal implants remains relatively limited, particularly with respect to long-term clinical outcomes.
Regarding transparency, the study states that the research received funding from the Herston Biofabrication Institute. No specific conflicts of interest are reported in the information provided. The conclusions should therefore be interpreted within the context of an evolving body of evidence that still requires confirmation through well-designed prospective clinical studies.
9. Key Study Highlights
- Study type: Narrative literature review.
- Level of evidence: Moderate; lower than a systematic review or meta-analysis because no systematic methodology is described.
- Population or studies reviewed: Not specified in the available information. The review synthesizes historical and contemporary publications on subperiosteal implants.
- Number of patients or implants: Not reported as a pooled cohort; individual studies included in the review vary substantially in sample size.
- Follow-up period: Variable across the reviewed literature, ranging from short-term evaluations to several decades in historical studies.
- Primary outcome evaluated: Historical evolution, clinical performance, implant survival, biological and mechanical complications, and future developments of subperiosteal implants.
- Principal finding: Digital technologies have significantly improved implant design and manufacturing, but hardware exposure, peri-implant infection, and implant mobility remain the most frequently reported complications.
- Scientific conclusion: Modern subperiosteal implants may represent a viable option for selected patients with complex anatomical limitations; however, stronger long-term clinical evidence is still required before wider implementation can be recommended.
- Main limitations: Heterogeneity of the available studies, absence of a systematic review methodology, and limited long-term evidence for contemporary patient-specific implant designs.
10. Scientific Impact
This review makes a valuable contribution by revisiting a treatment concept that has been largely overlooked for decades and evaluating it in light of modern digital implantology. Rather than simply documenting the historical decline of subperiosteal implants, the authors critically examine why earlier generations frequently failed and explore whether recent technological innovations may address many of those limitations.
One of the review’s main contributions is the integration of historical clinical experience with advances in contemporary digital workflows. Patient-specific CAD/CAM design, additive manufacturing, improved titanium processing, and prosthetically driven planning have transformed the way these implants can be conceived and manufactured. These developments suggest that current subperiosteal implants differ substantially from their historical predecessors, making direct comparisons between older and newer generations increasingly difficult.
The review also identifies several research priorities for the future, including optimization of implant design, enhancement of soft tissue management, improved fixation strategies, implant surface modifications, and the potential role of adjunctive bone grafting procedures. At the same time, the authors remain appropriately cautious, emphasizing that current evidence is based on relatively limited clinical experience and heterogeneous studies. Consequently, the review supports continued investigation rather than immediate expansion of clinical indications.
11. Editorial Conclusion
This review offers a balanced reassessment of subperiosteal implants within the context of contemporary implant dentistry. While historical experience clearly demonstrated important biological and mechanical limitations, advances in digital planning, CAD/CAM technology, and patient-specific titanium manufacturing have reopened the discussion regarding their potential clinical role. Current evidence suggests that these implants may become a valuable solution for carefully selected patients with severe anatomical deficiencies or complex post-oncologic defects. Nevertheless, the available literature remains limited, and well-designed prospective studies with long-term follow-up are still needed before subperiosteal implants can be considered a predictable alternative to conventional endosseous implant therapy.