1. Scientific Reference
- Study Title: Additively Manufactured Subperiosteal Implants for the Rehabilitations of Lateral Incisors Agenesis – A Case Series
- Authors: Marco Roy, Mauro Cerea, Wieslaw Hedzelek, Luigi Angelo Vaira, Barbara Dorocka-Bobkowska
- Journal: Journal of Oral and Maxillofacial Surgery, Medicine, and Pathology
- Year: 2025
- DOI: 10.1016/j.jormas.2025.102263
2. Scientific Background
Maxillary lateral incisor agenesis is one of the most challenging conditions in restorative dentistry and implantology, particularly when congenital tooth absence is accompanied by localized alveolar bone deficiency. In these patients, limited bone volume often compromises the placement of conventional endosseous implants, even when bone augmentation procedures are performed. Consequently, achieving a predictable implant-supported rehabilitation in the esthetic zone remains a demanding clinical objective.
Recent advances in digital planning and additive manufacturing have renewed interest in custom-designed subperiosteal implants. Unlike conventional implant systems, these patient-specific devices are designed to conform to the individual’s anatomical morphology, potentially offering an alternative solution in cases where insufficient bone volume precludes standard implant placement. The present study explores this emerging concept by evaluating the clinical performance of customized additively manufactured subperiosteal implants in patients with maxillary lateral incisor agenesis who had previously experienced early failure of conventional endosseous implants.
3. Study Objective
The primary objective of this investigation was to assess the clinical performance of patient-specific additively manufactured subperiosteal implants for the rehabilitation of maxillary lateral incisor agenesis associated with severe localized bone atrophy. The authors specifically aimed to determine whether this customized approach could provide a reliable alternative for patients with previous early failure of conventional endosseous implants by evaluating implant stability, peri-implant tissue health, esthetic outcomes, and prosthetic performance during clinical follow-up.
4. Methodology
This retrospective case series included 12 patients (10 females and 2 males) with a mean age of 25 ± 2.3 years. A total of 16 customized subperiosteal implants manufactured through additive manufacturing technology were placed to rehabilitate maxillary lateral incisor agenesis. All participants had previously experienced early failure of conventional endosseous implants.
The surgical protocol combined placement of patient-specific subperiosteal implants with bovine bone grafting and platelet-rich fibrin (PRF) membranes. Immediate loading was performed to achieve appropriate prosthetic positioning in the anterior maxilla.
Patients were followed for 18 to 64 months, with a mean follow-up of 48 ± 6.7 months. Clinical assessment focused on implant stability, peri-implant soft tissue health, probing depth, bleeding on probing, esthetic outcomes, and prosthetic performance. The available abstract does not provide additional details regarding statistical analysis or specific inclusion and exclusion criteria.
5. Main Findings
Throughout the observation period, no implant failures were reported, and all sixteen customized subperiosteal implants remained clinically stable. The biological evaluation demonstrated favorable peri-implant conditions, with a mean probing depth of 3 mm and only minimal evidence of peri-implant inflammation.
Soft tissue esthetics were also favorable. The reported mean Pink Esthetic Score (PES) was 12.3 ± 1.1, with individual values ranging from 10 to 14, indicating satisfactory esthetic integration of the restorations.
From a prosthetic perspective, complications were limited. Only two crowns required recementation after three years, while no biological complications or implant losses associated with these prosthetic events were reported.
Overall, the authors observed a 100% implant success rate within the follow-up period included in this study. However, they emphasize that these findings should be interpreted cautiously because of the limited sample size and the need for longer-term clinical evaluation before definitive conclusions regarding long-term reliability can be established.
6. Clinical Analysis
This case series highlights the potential role of customized additively manufactured subperiosteal implants in one of the most demanding indications in implant dentistry: the rehabilitation of maxillary lateral incisor agenesis in patients with localized alveolar bone atrophy and previous implant failure. In these situations, inadequate bone volume often limits the predictability of conventional endosseous implant therapy, even when bone augmentation procedures are considered.
The outcomes reported in this study suggest that a patient-specific subperiosteal implant, designed according to individual anatomical characteristics, may provide stable implant support while maintaining healthy peri-implant tissues and favorable esthetic integration over the reported follow-up period. The possibility of immediate loading is particularly relevant in the anterior maxilla, where both functional rehabilitation and esthetic demands are high.
Nevertheless, these findings should be interpreted within the context of the study design. As a retrospective case series without a control group, the investigation cannot establish superiority over conventional implant therapy, guided bone regeneration, or alternative reconstructive approaches. Instead, it provides preliminary clinical evidence supporting the feasibility of this personalized treatment concept in carefully selected patients who have limited therapeutic options.
Although the reported clinical outcomes are encouraging, further prospective controlled studies involving larger patient populations and extended follow-up periods will be necessary to determine the long-term predictability, biological behavior, and reproducibility of this technique before broader clinical recommendations can be made.
7. Clinical Applications
Based on the findings presented in this study, customized additively manufactured subperiosteal implants may represent a valuable treatment alternative for patients with maxillary lateral incisor agenesis associated with significant localized bone atrophy, particularly when previous conventional endosseous implant therapy has failed.
The proposed protocol integrates digital treatment planning, patient-specific implant design, additive manufacturing, bone grafting, and immediate prosthetic rehabilitation into a single therapeutic workflow. According to the available data, this approach appears particularly suitable for carefully selected cases in which conventional implant placement is not feasible because of insufficient bone volume.
However, the study specifically investigated a highly selected patient population. Therefore, its findings should not be generalized to other forms of maxillary atrophy, generalized edentulism, or different clinical indications without additional supporting evidence from higher-level clinical research.
8. Level of Evidence, Limitations, and Transparency
This publication is a retrospective case series, representing a low level of clinical evidence within the hierarchy of evidence-based medicine. While this type of study is valuable for evaluating the feasibility and early clinical performance of an innovative therapeutic approach, it cannot establish comparative effectiveness or demonstrate superiority over existing treatment modalities.
Several methodological limitations should be considered. The study included a small cohort of 12 patients receiving 16 customized implants, limiting the generalizability of the findings. In addition, the authors acknowledge that longer-term follow-up is required to determine the durability of the reported outcomes. The absence of a control group also prevents direct comparison with conventional endosseous implants or alternative bone reconstruction protocols.
No information regarding conflicts of interest, industry affiliations, or financial relationships with implant manufacturers is provided in the available abstract. Consequently, no conclusions can be drawn regarding potential sources of bias. Overall, the results should be viewed as preliminary clinical evidence that warrants confirmation through larger prospective and comparative clinical investigations.
9. Key Study Highlights
- Study design: Retrospective case series.
- Level of evidence: Low (observational descriptive study).
- Study population: 12 patients with maxillary lateral incisor agenesis and previous early failure of conventional endosseous implants.
- Number of implants: 16 patient-specific additively manufactured subperiosteal implants.
- Mean patient age: 25 ± 2.3 years.
- Follow-up period: 18 to 64 months (mean: 48 ± 6.7 months).
- Primary outcomes evaluated: Implant stability, peri-implant tissue health, esthetic outcomes, and prosthetic performance.
- Main clinical outcome: No implant failures were reported throughout the follow-up period, corresponding to a reported 100% implant success rate within this cohort.
- Biological outcomes: Mean probing depth of 3 mm with minimal peri-implant inflammation.
- Esthetic outcomes: Mean Pink Esthetic Score of 12.3 ± 1.1 (range: 10–14).
- Prosthetic complications: Two crowns required recementation after three years; no implant loss or major prosthetic complications were reported.
- Scientific conclusion: Customized additively manufactured subperiosteal implants may represent a promising treatment option for carefully selected patients with severe localized bone deficiency and previous failure of conventional implant therapy.
- Main limitations: Small sample size, retrospective study design, absence of a control group, and the need for longer-term follow-up.
10. Scientific Impact
This study contributes valuable preliminary clinical evidence regarding the use of patient-specific additively manufactured subperiosteal implants in a highly challenging indication characterized by localized anterior maxillary bone deficiency. Rather than focusing on generalized maxillary atrophy, the authors investigate a specific clinical scenario in which conventional implant therapy had already failed, thereby expanding the potential applications of customized subperiosteal implant technology.
The findings support the growing integration of digital implant planning, computer-aided design (CAD), and additive manufacturing into modern implant dentistry. By combining personalized implant design with immediate prosthetic rehabilitation, the proposed protocol illustrates how digital workflows may help overcome anatomical limitations that restrict conventional implant placement.
Despite these encouraging results, the study should be viewed as an exploratory contribution rather than definitive clinical evidence. The absence of comparative data prevents conclusions regarding superiority over established treatment strategies. Nevertheless, the reported outcomes provide a scientific basis for future prospective investigations designed to evaluate long-term survival, biological stability, prosthetic performance, patient-reported outcomes, and cost-effectiveness. Such research will be essential to determine the precise role of customized subperiosteal implants within contemporary implant rehabilitation protocols.
11. Editorial Conclusion
This retrospective case series presents encouraging short- to mid-term clinical outcomes for customized additively manufactured subperiosteal implants used in the rehabilitation of maxillary lateral incisor agenesis associated with severe localized bone atrophy. Within the limitations of the study, the technique demonstrated excellent implant stability, healthy peri-implant tissues, satisfactory esthetic integration, and minimal prosthetic complications.
However, because the evidence is derived from a small, uncontrolled retrospective cohort, these findings should be interpreted with appropriate caution. Larger prospective comparative studies with extended follow-up are required before this treatment approach can be considered an established alternative to conventional implant rehabilitation. Nevertheless, this study represents an important contribution to the expanding field of digitally designed, patient-specific implant solutions for anatomically challenging clinical situations.